See SOIREE Preliminary Voyage Report
See comments preserved from original file in dataset description as well
CTD data processing followed standard procedures.
These processes routinely result in pressure, temperature, salinity and
dissolved oxygen data that conform to WOCE Hydrographic Programme standards
(see WOCE HP Operations Manual WHP 91-1).
with the measurements referenced
to
(calibrated against) their respective international standards.
For SOIREE, the main exception was that there was no water-sample dissolved
oxygen data collected during the cruise. This meant that the dissolved O2
data could not be reliably calibrated to WOCE standards and that they are
only crudely indicative. It would be possible to somewhat further enhance
these dissolved O2 data by applying a calibration from a previous or
following cruise that used the same sensor.
BCO-DMO Processing Notes
Generated from original ctd_sf6.xls file provided on the
Deep-Sea Research II 48 (2001) accompanying CD-Rom
BCO-DMO Edits
- parameter names modified to conform to BCO-DMO convention
- added 'T' to CTD Station number for compatibility with events in other spreadsheets
- date, time. Lat, lon added from SOIREE_Stations_MasterStationList.xls using GMT dates/times
- "-1" No data or Bad data flag changed to BCO-DMO standard of "nd"