* Sea-Bird SBE 9 Data File:
* FileName = C:\CTD\MV1101-Balch\09401.hex
* Software Version Seasave V 7.20g
* Temperature SN = 4209
* Conductivity SN = 2572
* Number of Bytes Per Scan = 44
* Number of Voltage Words = 5
* Number of Scans Averaged by the Deck Unit = 1
* Append System Time to Every Scan
* System UpLoad Time = Feb 07 2011 18:48:24
* NMEA Latitude = 49 31.82 S
* NMEA Longitude = 009 11.94 W
* NMEA UTC (Time) = Feb 07 2011 18:48:14
* Store Lat/Lon Data = Append to Every Scan
** SHIP: RV-Melville RV-Melville
** CRUISE: MV1101 MV-1101
** STATION: 094
** CAST: 01
** Event# 0941848
# interval = seconds: 0.0416667
# start_time = Feb 07 2011 18:48:24 [System UTC, first data scan.]
# <Sensors count="15" >
# <sensor Channel="1" >
# <!-- Frequency 0, Temperature -->
# <TemperatureSensor SensorID="55" >
# <SerialNumber>4209</SerialNumber>
# <CalibrationDate>05-Oct-2010 </CalibrationDate>
# <UseG_J>1</UseG_J>
# <A>4.37678235e-003</A>
# <B>6.44438270e-004</B>
# <C>2.17656588e-005</C>
# <D>1.69467919e-006</D>
# <F0_Old>1000.000</F0_Old>
# <G>4.37657769e-003</G>
# <H>6.44225069e-004</H>
# <I>2.17331621e-005</I>
# <J>1.69320881e-006</J>
# <F0>1000.000</F0>
# <Slope>1.00000000</Slope>
# <Offset>0.0000</Offset>
# </TemperatureSensor>
# </sensor>
# <sensor Channel="2" >
# <!-- Frequency 1, Conductivity -->
# <ConductivitySensor SensorID="3" >
# <SerialNumber>2572</SerialNumber>
# <CalibrationDate>21-Sep-10 </CalibrationDate>
# <UseG_J>1</UseG_J>
# <!-- Cell const and series R are applicable only for wide range sensors. -->
# <SeriesR>0.0000</SeriesR>
# <CellConst>2000.0000</CellConst>
# <ConductivityType>0</ConductivityType>
# <Coefficients equation="0" >
# <A>0.00000000e+000</A>
# <B>0.00000000e+000</B>
# <C>0.00000000e+000</C>
# <D>0.00000000e+000</D>
# <M>0.0</M>
# <CPcor>-9.57000000e-008</CPcor>
# </Coefficients>
# <Coefficients equation="1" >
# <G>-1.01992844e+001</G>
# <H>1.57134377e+000</H>
# <I>3.74440094e-004</I>
# <J>5.17863092e-005</J>
# <CPcor>-9.57000000e-008</CPcor>
# <CTcor>3.2500e-006</CTcor>
# <!-- WBOTC not applicable unless ConductivityType = 1. -->
# <WBOTC>0.00000000e+000</WBOTC>
# </Coefficients>
# <Slope>1.00000000</Slope>
# <Offset>0.00000</Offset>
# </ConductivitySensor>
# </sensor>
# <sensor Channel="3" >
# <!-- Frequency 2, Pressure, Digiquartz with TC -->
# <PressureSensor SensorID="45" >
# <SerialNumber>0914</SerialNumber>
# <CalibrationDate>04-AUG-2010</CalibrationDate>
# <C1>-4.348786e+004</C1>
# <C2>1.072445e-001</C2>
# <C3>5.364520e-003</C3>
# <D1>3.649793e-002</D1>
# <D2>0.000000e+000</D2>
# <T1>3.006798e+001</T1>
# <T2>-2.820967e-004</T2>
# <T3>5.568048e-006</T3>
# <T4>-3.897905e-008</T4>
# <Slope>1.00000000</Slope>
# <Offset>0.00000</Offset>
# <T5>0.000000e+000</T5>
# <AD590M>1.287890e-002</AD590M>
# <AD590B>-8.813534e+000</AD590B>
# </PressureSensor>
# </sensor>
# <sensor Channel="4" >
# <!-- Frequency 3, Temperature, 2 -->
# <TemperatureSensor SensorID="55" >
# <SerialNumber>4213</SerialNumber>
# <CalibrationDate>05-Oct-2010 </CalibrationDate>
# <UseG_J>1</UseG_J>
# <A>4.37531885e-003</A>
# <B>6.48275404e-004</B>
# <C>2.25444747e-005</C>
# <D>1.77570523e-006</D>
# <F0_Old>1000.000</F0_Old>
# <G>4.37511470e-003</G>
# <H>6.48061103e-004</H>
# <I>2.25114734e-005</I>
# <J>1.77417516e-006</J>
# <F0>1000.000</F0>
# <Slope>1.00000000</Slope>
# <Offset>0.0000</Offset>
# </TemperatureSensor>
# </sensor>
# <sensor Channel="5" >
# <!-- Frequency 4, Conductivity, 2 -->
# <ConductivitySensor SensorID="3" >
# <SerialNumber>2819</SerialNumber>
# <CalibrationDate>21-Sep-10 </CalibrationDate>
# <UseG_J>1</UseG_J>
# <!-- Cell const and series R are applicable only for wide range sensors. -->
# <SeriesR>0.0000</SeriesR>
# <CellConst>2000.0000</CellConst>
# <ConductivityType>0</ConductivityType>
# <Coefficients equation="0" >
# <A>0.00000000e+000</A>
# <B>0.00000000e+000</B>
# <C>0.00000000e+000</C>
# <D>0.00000000e+000</D>
# <M>0.0</M>
# <CPcor>-9.57000000e-008</CPcor>
# </Coefficients>
# <Coefficients equation="1" >
# <G>-1.03781454e+001</G>
# <H>1.46070728e+000</H>
# <I>-2.96284306e-003</I>
# <J>2.92833553e-004</J>
# <CPcor>-9.57000000e-008</CPcor>
# <CTcor>3.2500e-006</CTcor>
# <!-- WBOTC not applicable unless ConductivityType = 1. -->
# <WBOTC>0.00000000e+000</WBOTC>
# </Coefficients>
# <Slope>1.00000000</Slope>
# <Offset>0.00000</Offset>
# </ConductivitySensor>
# </sensor>
# <sensor Channel="6" >
# <!-- A/D voltage 0, Fluorometer, Seapoint -->
# <FluoroSeapointSensor SensorID="11" >
# <SerialNumber>SCF3004</SerialNumber>
# <CalibrationDate></CalibrationDate>
# <!-- The following is an array index, not the actual gain setting. -->
# <GainSetting>2</GainSetting>
# <Offset>0.000</Offset>
# </FluoroSeapointSensor>
# </sensor>
# <sensor Channel="7" >
# <!-- A/D voltage 1, PAR/Irradiance, Biospherical/Licor -->
# <PAR_BiosphericalLicorChelseaSensor SensorID="42" >
# <SerialNumber>4644</SerialNumber>
# <CalibrationDate>Sept 29, 2009</CalibrationDate>
# <M>1.00000000</M>
# <B>0.00000000</B>
# <CalibrationConstant>2604166666.67000010</CalibrationConstant>
# <Multiplier>1.00000000</Multiplier>
# <Offset>-0.54550000</Offset>
# </PAR_BiosphericalLicorChelseaSensor>
# </sensor>
# <sensor Channel="8" >
# <!-- A/D voltage 2, Transmissometer, Chelsea/Seatech/WET Lab CStar -->
# <TransChelseaSeatechWetlabCStarSensor SensorID="59" >
# <SerialNumber>CST1119DR</SerialNumber>
# <CalibrationDate>1 May 2008</CalibrationDate>
# <M>18.9700</M>
# <B>-1.1570</B>
# <PathLength>0.250</PathLength>
# </TransChelseaSeatechWetlabCStarSensor>
# </sensor>
# <sensor Channel="9" >
# <!-- A/D voltage 3, Free -->
# </sensor>
# <sensor Channel="10" >
# <!-- A/D voltage 4, Altimeter -->
# <AltimeterSensor SensorID="0" >
# <SerialNumber>1183</SerialNumber>
# <CalibrationDate></CalibrationDate>
# <ScaleFactor>15.000</ScaleFactor>
# <Offset>0.000</Offset>
# </AltimeterSensor>
# </sensor>
# <sensor Channel="11" >
# <!-- A/D voltage 5, Free -->
# </sensor>
# <sensor Channel="12" >
# <!-- A/D voltage 6, Oxygen, SBE 43 -->
# <OxygenSensor SensorID="38" >
# <SerialNumber>1138</SerialNumber>
# <CalibrationDate>24-Mar-10p</CalibrationDate>
# <Use2007Equation>1</Use2007Equation>
# <CalibrationCoefficients equation="0" >
# <!-- Coefficients for Owens-Millard equation. -->
# <Boc>0.0000</Boc>
# <Soc>0.0000e+000</Soc>
# <offset>0.0000</offset>
# <Pcor>0.00e+000</Pcor>
# <Tcor>0.0000</Tcor>
# <Tau>0.0</Tau>
# </CalibrationCoefficients>
# <CalibrationCoefficients equation="1" >
# <!-- Coefficients for Sea-Bird equation - SBE calibration in 2007 and later. -->
# <Soc>4.7960e-001</Soc>
# <offset>-0.5235</offset>
# <A>-3.0266e-003</A>
# <B> 1.0957e-004</B>
# <C>-1.9445e-006</C>
# <D0> 2.5826e+000</D0>
# <D1> 1.92630e-004</D1>
# <D2>-4.64800e-002</D2>
# <E> 3.6000e-002</E>
# <Tau20> 2.0900</Tau20>
# <H1>-3.3000e-002</H1>
# <H2> 5.0000e+003</H2>
# <H3> 1.4500e+003</H3>
# </CalibrationCoefficients>
# </OxygenSensor>
# </sensor>
# <sensor Channel="13" >
# <!-- A/D voltage 7, Free -->
# </sensor>
# <sensor Channel="14" >
# <!-- SPAR voltage, Unavailable -->
# </sensor>
# <sensor Channel="15" >
# <!-- SPAR voltage, SPAR/Surface Irradiance -->
# <SPAR_Sensor SensorID="51" >
# <SerialNumber>6369</SerialNumber>
# <CalibrationDate></CalibrationDate>
# <ConversionFactor>1831.50000000</ConversionFactor>
# <RatioMultiplier>1.00000000</RatioMultiplier>
# </SPAR_Sensor>
# </sensor>
# </Sensors>
# datcnv_date = Mar 23 2011 13:58:48, 7.21c
# datcnv_in = c:\mv1101\ctd\09401.hex c:\mv1101\ctd\00101.xmlcon
# datcnv_ox_hysteresis_correction = yes
# datcnv_ox_tau_correction = yes
# datcnv_bottle_scan_range_source = scans marked with bottle confirm bit, 0, 2
# datcnv_scans_per_bottle = 49
# bottlesum_date = Mar 23 2011 14:51:35, 7.21c
# bottlesum_in = c:\mv1101\ctd\09401.ros C:\mv1101\ctd\00101.XMLCON c:\mv1101\ctd\09401.BL