cruise_id |
Cruise identifier
|
unitless |
cruise_id |
Start_ISO_DateTime_UTC |
Datetime (UTC) at start of collection; in ISO8601 format: YYYY-MM-DDThh:mmZ
|
unitless |
ISO_DateTime_UTC |
date_start_HST |
Local date (HST) at start of collection; format: YYYY-MM-DD
|
unitless |
start_date |
time_start_HST |
Local time (HST) (24 hour) at start of collection; format: hhmm
|
unitless |
time |
End_ISO_DateTime_UTC |
Datetime (UTC) at end of collection; in ISO8601 format: YYYY-MM-DDThh:mmZ
|
unitless |
ISO_DateTime_UTC |
date_end_HST |
Local date (HST) at end of collection; format: YYYY-MM-DD
|
unitless |
end_date |
time_end_HST |
Local time (HST) (24 hour) at end of collection; format: hhmm
|
unitless |
time |
sta |
Station number
|
unitless |
station |
lon_start |
Longitude (degrees E) at start of collection
|
decimal degrees |
lon_start |
lat_start |
Latitude (degrees N) at start of collection
|
decimal degrees |
lat_start |
lon_end |
Longitude (degrees E) at end of collection
|
decimal degrees |
lon_end |
lat_end |
Latitude (degrees N) at end of collection
|
decimal degrees |
lat_end |
samplesize_L |
Liters of water through entire filter
|
liters (L) |
sample_volume |
subsamplesize_L |
Liters of water through filter punch subsample
|
liters (L) |
sample_volume |
PC_GFF |
Total Particulate Carbon (PC) [umol/L] on first filter GF/F (nominal pore size 0.7um), prefiltered with 53um mesh, size range = 53 to 0.7um; filter punches not acidified before analysis; measurements corrected for 6 blank (dry) filters
|
micromole per liter (umol/L) |
TPC |
PC_GF75 |
Particulate Carbon (PC) [umol/L] on second filter GF75 (nominal pore size 0.3um), size range = 0.7 to 0.3um, filter punches not acidified before analysis; measurements corrected for 6 blank (dry) filters
|
micromole per liter (umol/L) |
C |
P13C_GFF |
Delta-13C of PC (permil vs. VPDB) on first filter GF/F (nominal pore size 0.7um), prefiltered with 53um mesh, size range = 53 to 0.7um; filter punches not acidified before analysis. Analytical uncertainty 0.1 permil
|
permil vs. VPDB |
d13C |
P13C_GF75 |
Delta-13C of PC (permil vs. VPDB) on second filter GF75 (nominal pore size 0.3um) size range = 0.7 to 0.3um, filter punches not acidified before analysis. Analytical uncertainty 0.1 permil
|
permil vs. VPDB |
d13C |
PN_GFF |
Particulate Nitrogen (PN) [umol/L] on first filter GF/F (nominal pore size 0.7um), prefiltered with 53um mesh, size range = 53 to 0.7um; filter punches not acidified before analysis; measurements corrected for 6 blank (dry) filters
|
micromole per liter (umol/L) |
PON |
PN_GF75 |
Particulate Nitrogen (PN) [umol/L] on second filter GF75 (nominal pore size 0.3um), size range = 0.7 to 0.3um, filter punches not acidified before analysis; measurements corrected for 6 blank (dry) filters
|
micromole per liter (umol/L) |
PON |
P15N_GFF |
Delta-15N of PN (permil vs. air-N2) on first filter GF/F (nominal pore size 0.7um), prefiltered with 53um mesh, size range = 53 to 0.7um; filter punches not acidified before analysis. Note there is no P15N_GF75 data, all samples from the second filter were below detection, detection limit ~0.75 micromol N. Analytical uncertainty 0.2 permil
|
permil vs. air-N2 |
d15N |