Particulate Organic Carbon. Units may be micrograms/Liter, milligrams/Liter or milligrams/meter^3
Particulate organic carbon derived from bbp (700 nm); The relationship between corrected bbp(700 nm) measured by the float backscatter sensor (bbp700_corr derived above) and POC concentrations measured in bottle samples collected during concurrent Bermuda Atlantic Time-series Study cruises (available at http://www.bco-dmo.org/project/2124 or http://bats.bios.edu) was utilized to predict POC concentration from corrected bbp(700 nm) for all float samples.
Linear regression yields the relationship:
POC [mg/m3] = bbp(700 nm) [m-1] * 32020.0874 + 0.2973; R2 = 0.86.
See https://www.bco-dmo.org/dataset/728371 for bottle calibration data.