station_std |
standard station numbers (as opposed to consecutive station numbers)
|
number |
station_std |
cast |
CTD cast number
|
number |
cast |
lat_start |
latitude at the start of the cast
|
decimal degrees; negative = South of Equator |
lat_start |
lon_start |
longitude at the start of the cast
|
decimal degrees; negative = West of Greenwich |
lon_start |
day_gmt |
day of the month in Greenwich Mean Time (a.k.a.UTC)
|
two digit day |
day_gmt |
month_gmt |
month of the year in Greenwich Mean Time (a.k.a.UTC)
|
two digit month |
month_gmt |
year |
year
|
four digit year |
year |
time_start_gmt |
time at the start of the cast: "NMEA UTC (Time)"
|
HH:MM:SS |
time_start |
ISO_DateTime_UTC |
ISO 8601 standard date and time
|
ISO format |
ISO_DateTime_UTC |
press |
water pressure at the point of data collection; can be considered depth within certain conditions
|
decibars |
press |
depth_w |
water depth at the data collection point
|
meters |
depth_w |
temp |
water temperature [ITS-90] from primary sensor
|
degrees C |
temp |
temp_2 |
water temperature [ITS-90] from secondary sensor
|
degrees C |
temp |
temp_diff |
temperature difference; secondary sensor - primary sensor
|
degrees C |
temp |
cond |
conductivity from primary sensor
|
milliSiemens per centimeter [mS/cm] |
cond_mS |
cond_2 |
conductivity from secondary sensor
|
milliSiemens per centimeter [mS/cm] |
cond_mS |
O2_um_Kg |
dissolved oxygen from primary CTD sensor
|
micromoles per Kilogram |
O2_umol_kg |
O2_ml_L |
dissolved oxygen from primary CTD sensor
|
milliliters per Liter |
O2_ml_L |
O2_um_Kg_2 |
dissolved oxygen from secondary CTD sensor
|
micromoles per Kilogram |
O2_umol_kg |
O2_ml_L_2 |
dissolved oxygen from secondary CTD sensor
|
milliliters per Liter |
O2_ml_L |
fluor |
fluorescence
|
milligrams per cubic meter |
fluor |
lat |
latitude
|
decimal degrees; negative = South |
lat |
lon |
longitude
|
decimal degrees; negative = West |
lon |
sal_diff |
practical salinity difference; secondary sensor - primary sensor
|
PSU |
sal_diff |
cond_diff |
conductivity difference; secondary sensor - primary sensor
|
milliSiemens per centimeter [mS/cm] |
cond_mS |
sigma_t |
water density from primary sensors
|
kilograms per cubic meter - 1000 |
sigma_t |
density_2 |
water density from secondary sensors
|
kilograms per cubic meter |
density |
potemp |
Potential Temperature [ITS-90] from primary sensors
|
degrees C |
potemp |
potemp_2 |
Potential Temperature [ITS-90] from secondary sensors
|
degrees C |
potemp2 |
sound_vel |
sound velocity [using Chen-Millero equation]
|
meters per second |
sound_vel |
sal |
salinity from primary sensor
|
practical salinity units (PSU) |
sal |
sal_2 |
salinity from secondary sensor
|
practical salinity units (PSU) |
sal2 |